Sumario
Info SECLA
Inforevista
Editorial
Paso a Paso
Día a Día
Nuevas tecnologías
Rincón del Residente
Noticias
Cursos y Congresos
Cartas a Endosurgery
Revisiones Bibliográficas
Foro
Informe Encuesta
Videoteca
Indice de Artículos
VIII CONGRESO SECLAVIII Congreso SECLA SantanderSitio Web:
www.secla2009.com

 

 


powered by FreeFind
 
HEMOSTASIA QUIRÚRGICA GONZÁLEZ FERNÁNDEZ, A.Servicio de Cirugía General y Digestiva.
Hospital de Segovia

V. BIBLIOGRAFÍA

  1. Sauaia A et al. Epidemiology of trauma deaths: a reassessment. J Trauma 1995;38:185-193
  2. Mattox KL et al. Disorders of surgical hemostasis and blood transfusion therapy  In: Hardy et al, eds Hardy´s Textbook of surgery 2nd ed. Philadelfia, PA. JB Lippincott Company 1988:67-75.
  3. Sharp KW, Locicero RJ. Abdominal packing for surgically uncontrollable hemorrhage. Ann Surg 1992;215: 467-175
  4. Zama N, Fazio VW Jagelman DG et al. Efficacy of pelvis parking in maintaining haemostasis after rectal excision for cancer. Dis Col Rectum 1988;31:923-8.
  5. Asensio JA. Exsanguination from penetrating injuries. Trauma 1990; 6:1-25.   
  6. Asensio J, Rojo E, Petrone F, Karsidag T, Pardo M, Demiray S et al. Síndrome de Exanguinación. Factores predictivos  e indicativos para la Institución de la Cirugía de Control de Daños. Cir Esp 2003; 73:120-129.
  7. Asensio JA, Petrone P, Roldan G, Kuncir E, Ramicone E, Chan L. Has evolution in awareness of guidelines for institution of damage control improved outcome in the management of posttraumatic open abdomen? Arch Surg 2004;139:209-14
  8. Poggetti RS, Moore EE, Moore FA, Mitchell MB, Read RA: Ballon tamponade for bilobar transfixing hepatic gunshot wounds. J Trauma 1992; 33: 694-7
  9. Kraus KK, Howells GA. Hypothermia induced coagulopathy during hemorrhagic shock. Am Surg 2000;66:348-54.
  10. Rotondo MF, Mc Gonigol MD, Schwab CW, Kauder DR, Hanson CW. Damage Control: An approach for improved survival in exanguinating penetrating abdominal injury. J Trauma 1993; 35:375-83.    
  11. Johnson J, Gracias V, Gupta R. Hepatic Angiography in patients undergoing Damage Control Laparotomy. J Trauma 2002; 52:1102-1106. 
  12. Denton JR, Moore EE, Coldwell DM. Multimodality treatment for grade V hepatic injuries: perihepatic packing, arterial embolization and venous stenting. J Trauma 1997; 42: 964.
  13. Chapman WC, Clavien P, Fung JJ, Block JE: Managing hepatic bleeding with autologous plasma, collagen-based fibrin sealant. Arch Surg 2001;136:966-7.
  14. Basu S, Marini CP, Bauman FG et al.: Comparative study of biological glues: cryoprecipitate glue, two component fibrin sealant, and “French” glue. Ann Thorac Surg 1995; 60:1255.
  15. Lerner R, Binur NS. Current status of surgical adhesives. J Surg Res 1990; 48:165.
  16. Banninger H, Hardegger T, Tobler A, et al. Fibrin glue in surgery: frequent development of inhibitors of bovine thrombin and human factor V. Br J Haematol 1993;85:528.
  17. Hanks JB, Kjaergard HK, Hollingsbee DA. A comparison of the haemostatic effect of VIVOSTAT patient derived-fibrin sealant with Oxidised Cellulose (SURGICEL) in multiple surgical procedures. Eur Surg Res 2003; 35:439-444.
  18. Chung F, Minon J, Dillarnd TF. Acute postoperative retroperitoneal fibrosis and ureteral obstruction secondary to the use of Avitene. Am J Obstet Gynecol 1978; 132:908-909.
  19. Chapman WC, Clavien P, Fung JJ, Block JE: Managing hepatic bleeding with autologous plasma, collagen-based fibrin sealant. Arch Surg 2001;136:966-7.
  20. Vistnes LM, Goodwin DA, Tenery JH etal. Control of capillary blending by topical application of microcristaline collagen. Surgery 1976;76:291.
  21. -W Browder, MS Litwin. Use of absorbable collagen for hemostasis in general surgery. Ann Surg 1986;52(9):492-494.
  22. Frilling A, Stavrou GA, Mischinger HJ et al. Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial. Langenbecks Arch Surg 2005;390: 114-120
  23. Weaber FA, Hood DB, Zatina M. Gelatin-Thrombin based hemostatic sealant for intraoperative bleeding in vascular surgery. Ann Vasc Surg 2002;16(3):286-293.
  24. Mallet SV, Cox D, Burroughs AK, Rolles K. Aprotinin and reduction of blood loss and liver requeriments in orthotopic liver transplantation. Lancet 1990;336:382.
  25. Royston D. Aprotinin versus lysine analogues: the debat continues. Ann Thorac Surg 1998;65:9-19.
  26. Kaspar M, Ramsey MAE, Nguyen AT, Cogswell M et al. Continous small-dose tranexamic acid reduces fibrinolysis but not transfusion requirements during orthotopic liver transplantation. Anesth Anal 1997;85:1-6.
  27. Arnal D, Piñeiro P, Garutti I, et al. Factor VII activado recombinante en un paciente con hemorragia incoercible por lesión traumática hepatorrenal. Rev Esp Anestesiol Reanim 2004;51:284-288.
  28. Kennedy JS, Stranahan PL, Taylor KD, et al. High-burst-strength, feedback controlled bipolar vessel sealing. Surg.Endosc 1998;12: 876-878.
  29. Tucker RD. Laparoscopic electrosurgical injuries. Surg Endosc 1995;5:311-317.
  30. Nduka CC, SuperPA, Monson JRT et al. Cause and prevention of electrosurgical injuries in laparoscopy. J Am Coll Surg 1994;179:161-9.
  31. Brill AI. Energy systems for operative laparoscopy. In J Am Assoc Gynecol Laparosc 1998; 5(4): 335-344.
  32. Gazelle GS, Goldberg SN, Solbiati L, Livraghi T. Tumor ablation with radiofrequency energy. Radiology 2000;217:633-646.
  33. Berber E, Herceg NL, Casto KJ, Siperstein AE. Laparoscopic radiofrequency ablation of hepatic tumors: prospective clinical evaluation of ablation size comparing two treatment algorithms. Surg Endosc 2004;18: 390-396.
  34. Navarra G, Lorenzini C, Curró G, Basaglia E and Habib NH. Early results alter radiofrequency-assisted liver resection. Tumori 2004;90:32-35.
  35. -Mulier S, Mulier P et al. Complications of radiofrequency coagulation of liver tumours. Br J Surg 2002; 89:1206-1222.
  36. Croce E, Azzola M, Russo R et al. Laparoscopic liver tumour resection with the argon beam. Endosc Surg Allied Technol 1994;2:186-188.
  37. Barre C, Pocholle P, Chauveau P. Minimal blood loss in patients undergoing radical retropubic prostatectomy. World J Surg 2002; 26:1094-8.
  38. Landman J, Kerbl K, Rehman J et al. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcin model. J Urol 2003; 169:697-700.
  39. Absten GT. Láser versus electrocirugía: Revisión, En: Microabordajes Ginecología.
    Grochmal S 1ªed. Barcelona: Ancora;1996:37-68.
  40. Poppas DP and Schlossberg SM. Laser tissue welding in urologic surgery. Urology 1994;43:143
  41. Tramberg KG, Rigotti P, Brackett KA et al. Liver resection: A comparison using Nd-YAG laser and ultrasonic surgical aspirator, or blunt dissection. Am J Surg 1986;151:368-373.
  42. Amaral JF. The experimental development of an ultrasonically activated scalpel. J Am Assoc Gynecol Laparosc 1996;3:601-608.
  43. Little M, Hollands MG. Impact of the CUSA and Operative Ultrasound on hepatic resection. MPB Surgery 1991; 13:271-8
  44. Addonizio JC. Cavitron in urologic surgery. Urol Clin North Am 1986;13: 445-454
  45. Yamamoto Y, Ikai I, Kume M et al. New simple technique for hepatic  parenchymal resection using a Cavitron Ultrasonic Surgical Aspirator and bipolar cautery equipped with a channel for water dripping. World J Surg 1999;23(10):1032-1037.
  46. Hodsom WJ, Morgan S. Hepatic resections for primary and metastatic tumours using the ultrasonic surgical dissector. Am J Surg 1992; 163:246-250.
  47. Ortega J, Sala C Flor B et al. Efficacy and cost-effectiveness of the Ultracision Harmonic Scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech 2004;14:9-12.
  48. Gossot D, Buess G. Ultrasonic dissection for endoscopic surgery. Surg Endosc 1999;13:412-417.
  49. Amstrong MG, Wayne L, Ambrozis MD. Harmonic scalpel vs electrocautery hemorroidectomy. Dis Col Rectum 2001;44:558-564.
  50. S Misika, G Deroide. Harmonic scalpel in laparoscopic colorectal surgery. Dis Col Rectum 2001;44:432-436.
  51. Hutchins R, Bertucci M. Experience with Tissue-Link–radiofrequency.assisted parenquimal division. Dig Surg 2007;24:318-321.
  52. Stern JA, Simon SD, Ferrigni RG et al. Tissue-Link device for laparoscopic Nephron sparing surgery. Endourology 2004; 18(5):455-6.
  53. Tabuse K. A new operative procedure of hepatic surgery using a microwave tissue coagulator. Nippon Geka Hokan 1979;72:133-140.

 

 

Página desarrollada por Edicorp. Webmaster:[email protected]